If output voltage of E-EGR actuator position sensor is higher than threshold value for more than 2.5 sec., ECM sets DTC P040600.
Item | Detecting Condition | Possible Cause | |
DTC Strategy |
•
Signal monitoring | 1. Poor connector connection 2. Short to power in signal circuit of E-EGR actuator 3. Faulty E-EGR actuator position sensor | |
Enable Conditions |
•
Engine running | ||
Threshold Value |
•
Output voltage of E-EGR actuator position sensor is higher than threshold value | ||
Diagnostic Time |
•
2.5 sec. | ||
Fail Safe | MIL |
•
On | |
EGR OFF |
•
Yes | ||
Torque Limit |
•
Yes | ||
DPF Regeneration OFF |
•
Yes |