DPF DPS | Terminal | Inspection Condition | Measured Value | Remarks | |
Pin No. | 1 | DPS Power |
•
Ignition switch "ON" & Engine "OFF"
•
Voltage is measured on wiring side(Disconnected) | Approx. 5V | - |
2 | DPS Signal | Approx. 5.6V | - | ||
3 | DPS Ground | 0 V | - |
DPF DPS | Terminal | Inspection Condition | Measured Value | Remarks | |
Pin No. | 1 | DPS Power |
•
Ignition switch "ON" & Engine "OFF"
•
Voltage is measured on wiring side(Connected) | Approx. 5V | - |
2 | DPS Signal | Approx. 1.0V | - | ||
3 | DPS Ground | 0 V | - |
Differential Pressure [△P] [kPa (kg/cm² / psi)] | Output Voltage (V) |
0 | 1 |
10 (0.1 / 1.45) | 1.35 |
20 (0.2 / 2.90) | 1.7 |
30 (0.3 / 4.35) | 2.05 |
40 (0.4 / 5.80) | 2.4 |
50 (0.5 / 7.25) | 2.75 |
60 (0.6 / 8.70) | 3.1 |
70 (0.7 / 10.10) | 3.45 |
80 (0.8 / 11.60) | 3.8 |
90 (0.9 / 13.00) | 4.15 |
100 (1.0 / 14.50) | 4.5 |