DTC Description

If shorted wiring or short to power in motor circuit of E-EGR actuator is detected, ECM sets DTC P049000.

DTC Detecting Condition

Item

Detecting Condition

Possible Cause

DTC Strategy

Signal monitoring

1.

Poor connector connection

2.

Shorted wiring or short to power in motor circuit of E-EGR actuator

3.

Faulty E-EGR actuator

Enable Conditions

Engine running

Threshold Value

Short to power in circuit

Short circuit between motor + and motor -

Diagnostic Time

2 sec.

Fail Safe

MIL

On

EGR OFF

Yes

Torque Limit

Yes

DPF Regeneration OFF

Yes