DTC Description

If output voltage of Fuel Temperature Sensor (FTS) is below threshold value for more than 3 sec., ECM sets DTC P018200.

DTC Detecting Condition

Item

Detecting Condition

Possible Cause

DTC Strategy

Voltage monitoring

1.

Short to ground in signal circuit of FTS

2.

Faulty FTS

Enable Condition

Engine running

Threshold Value

Output signal is below threshold value

Short to ground in signal circuit

Detecting Time

3 sec.

Fail Safe

MIL

Off