DTC Description

If ECM/PCM detects that the output signal satisfies the threshold values under enable conditions, ECM/PCM sets DTC P0130.

( This DTC might be caused by the malfunction of Heater circuit, so, check the heater circuit first. )

DTC Detecting Condition

Item

Detecting Condition

Possible Cause

DTC

Strategy

Rationality check

1.

Poor connection

2.

Damaged or corroded terminals

3.

HO2S (S1)

General

Enable

Conditions

Dew point end detected

Fuel feed back control active

Battery voltage is higher than 11V

Exhaust Gas temperature is higher than 280°C and lower than 800°C

No injector error

No upstream O2 sensor heater error

Case 1

Enable

Conditions

S2 sensor voltage is higher than 0.5V

Threshold

Value

S1 sensor voltage is higher than 0.06V and lower than 0.4V

Diagnostic Time

25 sec.

Case 2

Enable

Conditions

S2 sensor voltage is lower than 0.1V

Threshold

Value

S1 sensor voltage is higher than 0.6V and lower than 1.08V

Diagnostic Time

10 sec.

Case 3

Enable

Conditions

Continuous

Threshold

Value

Rate of heater pulse coupling to sensor signal is higher than 5 times per every 10 heating pulses

Diagnostic Time

The temperature difference between IAT and ECTS is lower than 20.3°C

MIL ON

Condition

3 driving cycles

※ S1 : upstream oxygen sensor / S2 : downstream oxygen sensor