If there is a short circuit to ground under enable conditions, the PCM sets DTC P0131.
Item | Detecting Condition | Possible Cause | |
DTC Strategy |
•
Electrical check | 1. Poor connection 2. Short to ground in signal circuit 3. HO2S (S1) | |
General Enable Conditions |
•
Dew point end detected
•
Fuel feed back control active
•
Battery voltage is higher than 11V
•
Exhaust Gas temperature is higher than 280°C and lower than 800°C
•
No injector error
•
No upstream O2 sensor heater error | ||
Case1 | Enabl Conditions |
•
S2 sensor voltage is higher than 0.5V | |
Diagnostic Time |
•
25 sec. | ||
Case2 | Enable Conditions |
•
Sensor in cold condition | |
Diagnostic Time |
•
0.1 sec. | ||
Threshold Value |
•
HO2S (S1) voltage is lower than 0.06V | ||
MIL ON Condition |
•
3 driving cycles |