Connect GDS to Data Link Connector(DLC).
IG KEY "ON" & ENG "OFF".
Perform "Actuation Test" for OCV.
Fig.1) Oil Control Valve - Intake Bank1 Actuation Test
Refer to Figure below (Also, operating sound(Clicking sound) is heard)
IG Key "OFF".
Disconnect OCV-IN connector.
Measure resistance between Pin No.2(Power) terminal and Pin No.1(Control) terminal of the OCV-IN. (Component Side)
Fig.1) 'Zero Set' Function
Specification : 9.4 ~ 10.4 [20°C(68°F)]
Does the OCV-IN operate properly and is the measured resistence within specification? (Check variation)
![]() | ▶ Fault is intermittent caused by poor contact in the sensor’s and/or ECM/PCM’s connector or was repaired and ECM/PCM memory was not cleared. Thoroughly check connectors for looseness, poor connection, bending, corrosion, contamination, deterioration, or damage. Repair or replace as necessary and go to "Verification of vehicle Repair" procedure. |
![]() | ▶ Carefully re-do this troubleshooting guide steps. ▶ If no problems were found with the circuits or connectors, replace the OCV-In and go to "Verification of Vehicle Repair" procedure. |