DTC Description

When an output voltage is approximately 0.45V or 3.5V for more than pre-defined time, ECM sets DTC P0134.

DTC Detecting Condition

Item

Detecting Condition

Possible Cause

DTC Strategy

•

Signal voltage monitoring

1.

Poor connector connection

2.

Short/open in upstream O2 sensor signal circuit

3.

Faulty upstream O2 sensor

General Enable

Condition

•

30 sec. elapsed after upstream dew point end detected

•

Fuel feedback control active

•

Battery voltage is higher than 11V

•

Exhaust gas temperature is at between 400℃(752℉) and 800℃(1472℉)

•

No injector error

•

No upstream O2 sensor heater error

Enable Condition

•

-

Threshold Value

•

Upstream O2 sensor voltage is at between 0.4V and 0.6V

Diagnosis Time

•

5 sec.

MIL ON Condition

•

3 driving cycles