DTC Description

When downstream O2 sensor signal output is not detected for pre-defined time, ECM sets DTC P0140.

DTC Detecting Condition

Item

Detecting Condition

Possible Cause

DTC Strategy

•

Signal monitoring

1.

Poor connector connection

2.

Short/open in downstream O2 sensor signal circuit

3.

Faulty downstream O2 sensor

General Enable

Condition

•

30 sec. elapsed after downstream dew point end detected

•

Battery voltage is higher than 11V

•

Exhaust gas temperature around O2 sensor is higher than 350℃(662℉)

•

No downstream O2 sensor heater error

Enable

Condition

Case 1

•

Time duration for target lambda(1.12) is 12 sec.

•

Lambda feedback control value is at between 0.95 and 1.05

Case 2

•

Time duration for target lambda(0.88) is 12 sec.

•

Lambda feedback control value is at between 0.95 and 1.05

•

Osciliation test not completed

Threshold

Value

Case 1

•

Downstream O2 sensor voltage is higher than 0.65V

Case 2

•

Downstream O2 sensor voltage is lower than 0.65V

Diagnostic Time

•

95 sec.

MIL ON Condition

•

3 driving cycles