DTC Description

If internal resistance is out of threshold value, ECM sets DTC P0141.

DTC Detecting Condition

Item

Detecting Condition

Possible Cause

DTC Strategy

Downstream O2 sensor heater performance monitoring

1.

Poor connector connection

2.

Faulty related fuse

3.

Open/short in power circuit

4.

Open/short in heater control circuit

5.

Faulty downstream O2 Sensor

Enable Condition

Exhaust gas temperature around O2 sensor is at between 350℃(662℉) and 650℃(1202℉)

Intake air temperature is higher than -7℃(19.4℉)

Battery voltage higher than 10.7 V and lower than 16.1 V

Threshold Value

Internal resistance is greater than threshold value (Calculated by exhaust gas temp. or heating power)

Diagnostic Time

15 sec.

MIL ON Condition

3 driving cycles