If excessive current is detected for more than 1 sec., ECM sets DTC P211100. This fault might be caused by short to power in control circuit or internal circuit error on ACV.
Item | Detecting Condition | Possible Cause | |
DTC Strategy |
•
Voltage monitoring | 1. Short to power in control (+) circuit of ACV 2. Short to power in control (-) circuit of ACV 3. Stuck opened ACV 4. Faulty ACV | |
Enable Conditions |
•
Engine running | ||
Threshold Value |
•
Short to power in control circuit or internal circuit error of ACV | ||
Diagnostic Time |
•
1 sec | ||
Fail Safe | MIL |
•
On | |
Torque Limit |
•
Yes | ||
DPF Regeneration OFF |
•
Yes |