TCM set this code when output voltage is out of available range.
Item | Detecting Condition | Possible cause |
DTC Strategy |
•
Check the voltage |
•
Open in signal circuit
•
Open in Power circuit
•
Faulty in TCM |
Enable Conditions |
•
IG ON | |
Threshold Value |
•
Input voltage < 2V | |
Diagnostic Time |
•
More than 1 second | |
Fail Safe |
•
Drive at Even gear |