Violation of function safety condition is detected, TCM sets DTC P060147.
Item | Detecting Condition | Possible Cause |
DTC Strategy |
•
Monitoring internal TCU H/W | 1. Defected TCM H/W |
Enable Condition |
•
- | |
Threshold Value |
•
Violation of function safety condition | |
Detecting Time |
•
Set after 7 times of reset | |
Fail Safe |
•
Neutral |