TCM set this code When Gear Actuator1 is not perceived reference position.
Item | Detecting Condition | Possible Cause |
DTC Strategy |
•
Monitoring maximum length of left/right gear shift motor1 | 1. Defected Gear Actuator1 2. Defected DCT 3. Mechanical failure on gear1 shift direction |
Enable Condition |
•
Gear shift motor 1 hall sensor is normal when reference point is found during engine cranking | |
Threshold Value |
•
Maximum motion of gear shift motor 1 is less than 19.4mm or greater than 22mm | |
Detecting Time |
•
3 events | |
Fail Safe |
•
Drive at Even gear |