Inspection
1.

Connect a GDS on Data Link Connector (DLC).

2.

Check MAPS output voltage at idle and IG ON.

Pressure

[kPa (kgf/cm², psi)]

Output Voltage (V) [Vref = 5V]

20.0 (0.20, 2.9)

0.79

46.7 (0.47, 6.77)

1.84

101.32 (1.03, 14.7)

4.0

Removal
1.

Turn ignition switch OFF and disconnect the battery negative (-) terminal.

2.

Disconnect the manifold absolute pressure sensor connector (A).

3.

Remove the installation screw (B), and then remove the sensor from the surge tank.

Installation
note
●

Install the component with the specified torques.

●

Note that internal damage may occur when the component is dropped. In this case, use it after inspecting.

●

Insert the sensor in the installation hole and be careful not to damage when installation.

1.

Installation is reverse of removal.