Inspection
1.

Turn ignition switch OFF.

2.

Disconnect IATS connector.

3.

Measure resistance between IATS terminals 3 and 4.

4.

Check that the resistance is within the specification.

Temperature

Resistance (㏀)

-40

-40

40.93 ~ 48.35

-30

-22

23.43 ~ 27.34

-20

-4

13.89 ~ 16.03

-10

14

8.5 ~ 9.7

0

32

5.38 ~ 6.09

10

50

3.48 ~ 3.90

20

68

2.31 ~ 2.57

30

86

1.9 ~ 2.1

40

104

1.08 ~ 1.21

50

122

0.76 ~ 0.85

60

140

0.54 ~ 0.62

70

158

0.40 ~ 0.45

80

176

0.29 ~ 0.34

90

194

0.22 ~ 0.26

100

212

0.17 ~ 0.20

110

230

0.13 ~ 0.15

120

248

0.10 ~ 0.12

130

266

0.08 ~ 0.09

Removal
1.

Turn ignition switch OFF and disconnect the battery negative (-) terminal.

2.

Disconnect the manifold absolute pressure sensor connector (A).

3.

Remove the installation screw (B), and then remove the sensor from the surge tank.

Installation
note

Install the component with the specified torques.

Note that internal damage may occur when the component is dropped. In this case, use it after inspecting.

Insert the sensor in the installation hole and be careful not to damage when installation.

1.

Installation is reverse of removal.