Inspection
1.

Turn ignition switch OFF.

2.

Disconnect IATS connector.

3.

Measure resistance between IATS terminals 3 and 4.

4.

Check that the resistance is within the specification.

Temperature

Resistance (㏀)

℃

℉

-40

-40

40.93 ~ 48.35

-30

-22

23.43 ~ 27.34

-20

-4

13.89 ~ 16.03

-10

14

8.5 ~ 9.7

0

32

5.38 ~ 6.09

10

50

3.48 ~ 3.90

20

68

2.31 ~ 2.57

30

86

1.9 ~ 2.1

40

104

1.08 ~ 1.21

50

122

0.76 ~ 0.85

60

140

0.54 ~ 0.62

70

158

0.40 ~ 0.45

80

176

0.29 ~ 0.34

90

194

0.22 ~ 0.26

100

212

0.17 ~ 0.20

110

230

0.13 ~ 0.15

120

248

0.10 ~ 0.12

130

266

0.08 ~ 0.09

Removal
1.

Turn ignition switch OFF and disconnect the battery negative (-) terminal.

2.

Disconnect the manifold absolute pressure sensor connector (A).

3.

Remove the installation screw (B), and then remove the sensor from the surge tank.

Installation
note
●

Install the component with the specified torques.

●

Note that internal damage may occur when the component is dropped. In this case, use it after inspecting.

●

Insert the sensor in the installation hole and be careful not to damage when installation.

1.

Installation is reverse of removal.