Install in the reverse order of removal.
When installing the battery, fix the mounting bracket on the tray correctly.
After disconnecting then reconnecting the battery negative cable, reset some parts that require the reset procedures.
(Refer to Body Electrical System - "General Information")
When installing the battery, fix the mounting bracket on the tray correctly.
ISG (Idle stop & go) system equipped vehicle uses the AGM battery only. Installing a flooded battery may potentially lead to engine electrical trouble or ISG system error.
Replace with an AGM battery of the same capacity.
Ensure that an AGM battery is fitted.
In all cases, an AGM battery must be installed and registered in the vehicle for the ISG function to work perfectly.
After replacing with a new battery, the vehicle must stand for at least 4 hours with the ignition switch OFF, doors closed and hood switch OFF.
ISG system stabilization may take 4 hours after installing a new battery.
After standing for 4 hours, the ISG function will operate with 2 cranks by the user.
However, for the first 25 times, the ISG function can operate regardless of ISG system stability for ISG function operation check.
Do not open the AGM battery.
The AGM battery must not be opened under any circumstances as the introduction of oxygen from the air will cause the battery to lose its chemical equilibrium and become non-operational.