Component Inspection
■ Perform OCV Actuation Test
1.

Connect GDS to Data Link Connector(DLC).

2.

IG KEY "ON" & ENG "OFF".

3.

Perform "Actuation Test" for OCV.

Fig.1) Oil Control Valve - Exhaust Bank1(Option) Actuation Test

■ Inspect OCV-EX
4.

IG Key "OFF".

5.

Disconnect OCV-EX connector.

6.

Measure resistance between Pin No.1(Power) terminal and Pin No.2(Control) terminal of the OCV-EX. (Component Side)

Specification : 9.4 ~ 10.4 [20℃(68℉)]

■ Confirm Part Inspection
7.

Does the OCV-EX operate properly and is the measured resistence within specification? (Check variation)

▶ Go to "Verification of Vehicle Repair" procedure.

▶ If no problems were found with the circuits or connectors, Replace the OCV-EX.