DTC Description

If the measured temperature is higher than the maximum threshold value during 2sec, ECM/PCM sets DTC P0112.

(In this case, the input signal voltage is the minimum threshold value.)

DTC Detecting Condition

Item

Detecting Condition

Possible Cause

DTC Strategy

•

Signal check, low

1.

Poor connection

2.

Short to ground in signal circuit

3.

IATS

Enable Conditions

•

Elapsed time after start is higher than 2 sec.

Threshold Value

•

Voltage less than 0.131 V(greater than 125 ℃/257 °F)

Diagnostic Time

•

2 sec.

Mil On Condition

•

3 driving cycles