DTC Description

ECM/PCM assumes that O2 sensor heater coil is abnormal and shows P0135 when the corrected resistance value of upstream O2 sensor heater is higher than the specification.

DTC Detecting Condition

Item

Detecting Condition

Possible Cause

DTC Strategy

•

Heater Performance Check

1.

Poor connection

2.

Open or Short to ground in power circuit

3.

Damaged or corroded terminals

4.

HO2S(S1)

Case 1

Enable

Conditions

•

B+ greater than 10.7V and less than 16.0 V

•

Sensor heating time greater than 45 sec.

Threshold

Value

•

Ceramic Temp less than 720 ℃(1328°F)

Diagnostic

Time

•

3 sec.

Case 2

Enable

Conditions

•

Exhaust Temp greater than 450 ℃(842 °F)

•

Power of Sensor heating greater than 90 %

•

Sensor heating time greater than 50 sec.

•

No Fuel Cut greater than 50 sec.

Threshold

Value

•

Ceramic Temp less than 720 ℃(1328 °F)

Diagnostic

Time

•

60 sec.

Case 3

Enable

Conditions

•

Exhaust Temp greater than 450 ℃(842 °F)

•

Sensor heating time greater than 50 sec.

•

No Fuel Cut greater than 50 sec.

Threshold

Value

•

Ceramic Temp less than 640 ℃(1184 °F)

Diagnostic

Time

•

10 sec.

MIL ON Condition

•

2 driving cycles

※ S1 : upstream oxygen sensor / S2 : downstream oxygen sensor

Яндекс.Метрика