DTC Description

P0197 is set when the EOTS output voltage is below the minimum value of 100mV for more than 3 sec. This code is due to short to ground in signal circuit.

DTC Detecting Condition

Item

Detecting Condition

Possible Cause

DTC Strategy

EOTS Circuit monitoring

1.

EOTS signal circuit short to ground.

2.

Faulty EOTS

Enable Conditions

Ignition switch "ON"

Threshold Value

EOTS signal circuit short to ground.

Fail Safe

Fuel Cut

NO

EGR Off

NO

Fuel Limit

NO

Check Lamp

NO