DTC Description

P0197 is set when the EOTS output voltage is below the minimum value of 100mV for more than 3 sec. This code is due to short to ground in signal circuit.

DTC Detecting Condition

Item

Detecting Condition

Possible Cause

DTC Strategy

•

EOTS Circuit monitoring

1.

EOTS signal circuit short to ground.

2.

Faulty EOTS

Enable Conditions

•

Ignition switch "ON"

Threshold Value

•

EOTS signal circuit short to ground.

Fail Safe

Fuel Cut

•

NO

EGR Off

•

NO

Fuel Limit

•

NO

Check Lamp

•

NO