DTC Description

If there is an abnormal response rate of HO2S under enable conditions, the PCM sets DTC P0133.

DTC Detecting Condition

Item

Detecting Condition

Possible Cause

DTC Strategy

•

Response rate monitor(6-Pattern Monitoring).

1.

Poor connection

2.

Leak or clog in intake air system

3.

Injector

4.

Fuel pressure

5.

HO2S(S1)

Enable Conditions

•

Upstream O2 Sensor Ceramic temp greater than 720 ℃(1328 °F).

•

ECT greater than 40.5 ℃(104.9 °F).

•

Purge mass duration greater than 5 sec.

•

Engine load greater than 25% and less than 65%.

•

Catalyst temp greater than 400 ℃(752 °F).

•

No fuel cut off.

•

Fuel system status equal to Closed Loop.

•

Engine speed and Engine speed greater than 1320 rpm and less than 3000 rpm.

Threshold Value

•

Compare ratio of Expected Area to Actual Area less than 0.35.

Diagnostic Time

•

10 switches in Lambda setpoint steps(5 for Lean-Rich, 5 for Rich-Lean).

Mil On Condition

•

2 driving cycles.

※ S1 : upstream oxygen sensor / S2 : downstream oxygen sensor