Connect GDS to Data Link Connector(DLC).
Ignition "ON"
Perform "Driver Mode Door-Vent", "Driver Mode Door-Floor" and "Driver Mode Door-Defrost" in "Actuation Test" with GDS.
Monitor "Direction Potentiometer-Driver" parameter in "Current Data" with GDS.
Specification : Driver Mode Door-Vent : 6.3% / Driver Mode Door-Floor% : 58.4% / Driver ModeDoor-Defrost : 93.7%
Is displayed parameter within specification?
![]() | ▶ Fault might be intermittent and caused either by poor contact in connectors or wiring harness, or it has been repaired and control module memory is not cleared yet. Thoroughly check terminal of battery, all connectors ( and connections) for looseness, bending, corrosion, contamination, deterioration, and/or damage. ▶ Repair or replace as necessary and then go to "Verification of Vehicle Repair" procedure. |
![]() | ▶ Carefully re-do this troubleshooting guide steps. ▶ If problem still occurs, replace Direction Potentiometer and then go to "Verification of Vechicle Repair" procedure. |