Check for continuity and measure the resistance between terminals.
| Connector | Resistanc (± 10%) |
Cushion (C) | 1-2 | 4.54 Ω |
Back (B) | 1-2 | 5.16 Ω |
Set (A) | 1-4 | 9.70 Ω |
Check for continuity and measure the resistance between terminals.
[LH]
[RH]
| Connector | Resistanc (± 10%) |
Cushion (A) | 1-4 | 4.13 Ω |
Performance of heater is the average temperature of seat surface.
The temperature of seat surface according to pushing the seat heater switch is as below.
| Type | 1st | 2nd | 3rd | |
First row seat | Cushion (±2°C/±35.6°F) | HI-Low | 38°C (100°F) | 42°C (107.6°F) | - |
3 Step | 36°C (96.8°F) | 39°C (102.2°F) | 42°C (107.6°F) | ||
Back (±2°C/±35.6°F) | HI-Low | 45°C (113°F) | 50°C (122°F) | - | |
3 Step | 40°C (104°F) | 45°C (113°F) | 50°C (122°F) | ||
Second row seat | Cushion (±2°C/±35.6°F) | HI-Low | 38°C (100.4°F) | 42°C (107.6°F) | - |