DTC Description

P0490 is set when the EEGR actuator circuit is short to battery.

DTC Detecting Condition

Item

Detecting Condition

Possible Cause

DTC Strategy

Signal monitoring

1.

EEGR actuator circuit short to battery

2.

Faulty EEGR actuator

Enable Conditions

IG "ON"

Threshold Value

EEGR actuator circuit is short to battery.

Fail Safe

Fuel Cut

NO

EGR Off

NO

Fuel Limit

YES

Check Lamp

YES