DTC Description

If there is an abnormal response rate of HO2S under enable conditions, the ECM/PCM sets DTC P0133.

DTC Detecting Condition

Item

Detecting Condition

Possible Cause

DTC Strategy

Slow response - Check Lambda Signa Amplitude

1.

Poor connection

2.

Leak or clog in intake air system

3.

Injector

4.

Fuel pressure

5.

HO2S(S1)

Enable Conditions

Sensor pump current valid No SPI(Serial Peripheral Interface) communication fault, P0606

& Battery Voltage > 10V

& Sensor Tip Temperature > 650°C

O2 sensor Forced stimulation active

P0420(Catalyst Diagnosis) monitoring active P0133 diagnosis is synchronized with P0420 monitor.

Threshold Value

Integral ( Lambda signal amplitude measured / Lambda signal amplitude of a slow sensor) > 1

Diagnostic Time

15 lambda controller cycles(SULEV)

Mil On Condition

2 driving cycles.

※ S1 : upstream oxygen sensor / S2 : downstream oxygen sensor