Component Inspection
■ Perform Injector Actuation Test
1.

Connect GDS to Data Link Connector(DLC).

2.

IG KEY "ON" & ENG "OFF".

3.

Perform "Actuation Test" for Injector

■ Confirm Part Inspection
14.

Does the Injector operate properly? (Check variation)

▶ Go to "Verification of Vehicle Repair" procedure.

▶ If no problems were found with the circuits or connectors, Replace the Injector #3.