DTC Description

P0112 is set when the voltage below 73mV - minimum output voltage of IATS(inside of AFS) - is detected for more than 1.0 sec. This code is due to short to ground in IATS signal circuit.

DTC Detecting Condition

Item

Detecting Condition

Possible Cause

DTC Strategy

•

MAFS circuit monitoring

1.

IATS signal circuit short to ground

2.

Faulty IATS #1

Enable Conditions

•

Ignition switch "ON"

Threshold Value

•

MAFS signal circuit short to ground

Fail Safe

Fuel Cut

•

NO

EGR Off

•

YES

Fuel Limit

•

NO

Check Lamp

•

YES

•

Output temperature is fixed at 50℃.