DTC Description

P0112 is set when the voltage below 73mV - minimum output voltage of IATS(inside of AFS) - is detected for more than 1.0 sec. This code is due to short to ground in IATS signal circuit.

DTC Detecting Condition

Item

Detecting Condition

Possible Cause

DTC Strategy

MAFS circuit monitoring

1.

IATS signal circuit short to ground

2.

Faulty IATS #1

Enable Conditions

Ignition switch "ON"

Threshold Value

MAFS signal circuit short to ground

Fail Safe

Fuel Cut

NO

EGR Off

YES

Fuel Limit

NO

Check Lamp

YES

Output temperature is fixed at 50℃.