DTC Description

P0117 is set when the voltage below 200mV - minimum output voltage of ECTS - is detected for more than 2.0 sec. This code is due to short to ground in signal circuit.

DTC Detecting Condition

Item

Detecting Condition

Possible Cause

DTC Strategy

•

ECTS circuit monitoring

1.

ECTS signal circuit short to ground

2.

Faulty ECTS

Enable Conditions

•

Ignition switch "ON"

Threshold Value

•

ECTS signal circuit short to ground

Fail Safe

Fuel Cut

•

NO

EGR Off

•

YES

Fuel Limit

•

NO

Check Lamp

•

YES

•

At cold condition or ranking : fixed to -10℃

•

During engine operation : 80℃