If the measured temperature is higher than the maximum threshold value, the PCM sets DTC P0117.
(In this case, the input signal voltage is the minimum threshold vaue.)
Item | Detecting Condition | Possible Cause |
DTC Strategy |
•
Signal check, low. | 1. Poor connection 2. Short to ground in signal circuit 3. ECTS |
Enable Conditions |
•
- | |
Threshold Value |
•
ECT sensor voltage less than 0.12 V(125.3 ℃/257.54 °F). | |
Diagnostic Time |
•
Continuous. | |
Mil On Condition |
•
2 driving cycles. |