Inspection
1.

Turn ignition switch OFF.

2.

Disconnect the VGT control solenoid valve connector.

3.

Measure resistance between terminal 1 and 2 of the valve.

4.

Check that the resistance is within the specification.

Specification: Refer to Specification section.

Removal
1.

Turn the ignition switch OFF and disconnect the battery negative (-) terminal.

2.

Disconnect the VGT control solenoid valve connector (A).

3.

Remove the VGT control solenoid valve (B) in the direction of the arrow.

4.

Remove the VGT control solenoid valve (B) after disconnect the vacuum hose (A).

Installation
1.

Install is reverse of removal.