Inspection
1.

Using an ohmmeter, measure the resistance between terminals 1 and 3 of sender connector (A) at each float level.

Capacity (ℓ)

Discription

1

Fuel sender signal

2

-

3

Fuel sender ground

4

-

2.

Also check that the resistance changes smoothly when the float is moved from "E" to "F".

Position

Resistance (Ω)

Capacity (ℓ)

E

197~203

4.3

 1/2

64.2~68.2

26.4

F

6~10

51.3