Self Diagnosis
1.

Self-diagnosis process

2.

How to read self-diagnostic code

After the display panel flickers three times every 0.5 second, the corresponding fault code flickers on the setup temperature display panel every 0.5 second and will show two figures. Codes are displayed in numerical format

3.

Fault code display

(1)

Continuance operation : DTC code is one.

(2)

Continuance operation : DTC code is more two.

(3)

STEP operation

A.

Nomal or one fault code is same as a continuance operation.

B.

DTC code os more two.

4.

If fault codes are displayed during the check, Inspect malfunction causes by referring to fault codes.

Display

Fail description

00

Normal

11

In-car sensor open

12

In-car sensor short

13

Ambient sensor open

14

Ambient sensor short

17

Evaporator sensor open

18

Evaporator sensor short

19

Temp door potentiometer open/short- Drive

20

Temp door potentiometer fault- Drive

21

Mode door potentiometer open/short

22

Mode door potentiometer fault

25

Intake door potentiometer open/short

26

Intake door potentiometer fault

45

APT CAN Signal Fault

47

RPM CAN Signal Fault

48

Vehicle speed Signal Fault

49

Engine coolant temperature CAN Signal Fault

50

Cluster ionizer fault

71

ECV fault

5.

Fail safe

NO.

Item

Fault

Fail Safe

1

In-car Sensor

Open or Short

Control with the value of 25°C(77.0°F)

2

Ambient temperature sensor

Open or Short

Control with the value of 20°C(67°F)

3

Evaporator temperature sensor

Open or Short

Control with the value of -2°C(28.4°F)

4

Water temperature sensor

Open or Short

Control with the value of -2°C(28.4°F)

5

Temperature control actuator

Open or Short

If temperature setting 17°C-24.5°C, fix at maximum cooling position.

If temperature setting 25°C-32°C, fix at maximum heating position.

6

Mode control actuator

Open or Short

Fix vent position, while selecting vent mode.

Fix defrost position, while selecting all except vent mode.

7

Intake control actuator

Open or Short

Fix fresh position, while selecting fresh mode.

Fix recirculation position, while selecting recirculation mode.

9

ECV

Open

CF_Fatc_EcvFlt = 01H (fault) ECV OFF, A/C Output OFF, Torque 0Nm

10

VS (Vehicle Speed)

FFh or NO reception

VS-TCU (From TCU2)

11

VS TCU (Vehicle Speed Calculated by TCU)

FFh or NO reception

Control with the value of  0 Kph

12

N (Engine Speed)

NO reception

Control with the value of 650 RPM

13

F_N_ENG

FFh or NO reception

Control with the value of 650 RPM

14

TPS (Throttle Position Signal)

FFh or NO reception

0%

15

Temp _ ENG

FFh or NO reception

Control with the value of - 2 ℃(28.4°F)

16

R _ TqAcnApvC (Max Torque Limitation of A/C Compressor)

FFh or NO reception

0 Nm (ECV OFF)

17

R _ PAcnC (APT Sensor Output Value)

FFh or NO reception

0 hPa (ECV OFF)

18

RLY _ AC

NO reception

Comp OFF (ECV OFF)

Replacement
1.

Disconnect the negative (-) battery terminal.

2.

Using a screwdriver or remover, remove the center fascia panel (A).

3.

Disconnect the A/C & heater controller connectors (A).

4.

Remove the heater & A/C controller unit (A) from the center fascia panel (B) after loosening the mounting screws.

5.

Install in the reverse order of removal.

caution

Make sure the connector are connected in properly.

Replace any damaged clips.