Inspection
First Row Seat
1.

Check for continuity and measure the resistance between terminals.

 

Connector

Resistanc

(± 10%)

Cushion (C)

1-2

4.54 Ω

Back (B)

1-2

5.16 Ω

Set (A)

1-4

9.70 Ω

Second Row Seat
1.

Check for continuity and measure the resistance between terminals.

[LH]

[RH]

 

Connector

Resistanc

(± 10%)

Cushion (A)

1-4

4.13 Ω

caution

Performance of heater is the average temperature of seat surface.

The temperature of seat surface according to pushing the seat heater switch is as below.

 

Type

1st

2nd

3rd

First row seat

Cushion

(±2°C/±35.6°F)

HI-Low 

38°C

(100°F)

42°C

(107.6°F)

3 Step

36°C

(96.8°F)

39°C

(102.2°F)

42°C

(107.6°F)

Back

(±2°C/±35.6°F)

HI-Low 

45°C

(113°F)

50°C

(122°F)

3 Step

40°C

(104°F)

45°C

(113°F)

50°C

(122°F)

Second row seat

Cushion

(±2°C/±35.6°F)

HI-Low 

38°C

(100.4°F)

42°C

(107.6°F)