Check for continuity and measure the resistance between terminals.
| Connector | Resistanc (± 10%) |
Cushion (C) | 1-4 | 4.54 Ω |
Back (B) | 1-4 | 5.16 Ω |
Set (A) | 3-4 | 9.70 Ω |
Performance of heater is the average temperature of seat surface.
The temperature of seat surface according to pushing the seat heater switch is as below.
| Type | 1st | 2nd | 3rd | |
First row seat | Cushion (±2℃/±35.6℉) | 3 Step | 36℃ (96.8℉) | 39℃ (102.2℉) | 42℃ (107.6℉) |
Back (±2℃/±35.6℉) | 40℃ (104℉) | 45℃ (113℉) | 50℃ (122℉) |