Component Location
General Description

The Evaporator sensor located on heater unit detects the core temperature. It is a negative type thermistor whose resistance is inversely proportional to temperature. Evaporator sensor transforms measured temperature into voltage value and delivers it to A/C ECU. when core temperature is blow threshold value, A/C ECU interrupts compressor relay power, in order to prevent evaporator freezing by excessive cooling.

DTC Description

Air conditioner Control Module sets DTC B1241 if Evaporator sensor has been detected below 0.1V for 4 seconds.

DTC Detecting Condition

Item

Detecting Condition

Possible Cause

DTC Strategy

Voltage check

1.

Short circuit in harness

2.

Faulty Evaporator sensor

3.

Faulty A/C Control Unit

Enable Conditions

IG KEY ON

Threshold value

Evaporator sensor has been detected below 01.V for 4 seconds.

Failsafe

Control with the value of -2℃(28.4℉)

Specification
※ Resistance value of evaporator sensor as a function of temperature.

Temperature(℃/℉)

Resistance(㏀)

Temperature(℃/℉)

Resistance(㏀)

-10/-14

18

20/68

4.8

0/32

11

30/86

3.3

10/50

7.3

40/104

2.3

Diagnostic Circuit Diagram
note
To view Flash content, you need to install the appropriate browser extension