Component Location
General Description

The ambient temperature sensor located at the center stay of the condensor detects ambient air temperature. It is a negative type thermistor whose resistance is inversely proportional to temperature. Its output is used for sensor fail-safe, temperature regulation door lock, blower motor level control, mix mode control and in-car humidity control.

DTC Description

Air conditioner Control Module sets DTC B1237 if Ambient sensor has been detected below 0.1V for 4 seconds.

DTC Detecting Condition

Item

Detecting Condition

Possible Cause

DTC Strategy

Voltage check

1.

Short in signal circuit

2.

Faulty Ambient Sensor

3.

Faulty A/C control Module

Enable Conditions

Ignition ON

Threshold value

Ambient sensor has been dtected 0.1V for 4 seconds.

Failsafe

Displayed '--' and A/C control Module regards and controls it as 20℃(68℉)

Specification
※ Resistance value of ambient temp.sensor as a function of temperature.

Temperature(℃/℉)

Resistance(㏀)

Temperature(℃/℉)

Resistance(㏀)

-20/-4

284.5

50/122

10.8

0/32

97.5

70/158

5.2

25/77

30

Diagnostic Circuit Diagram