Self-diagnosis process

How to read self-diagnostic code
During the self-diagnosis, the corresponding fault code flickers on the setup temperature display panel every 0.5 second and will show two figures.
Fault codes are displayed in numerical format.
| Display | Fail description | 
| 00 | Normal | 
| 11 | In-car sensor open | 
| 12 | In-car sensor short | 
| 13 | Ambient temperature sensor open | 
| 14 | Ambient temperature sensor short | 
| 15 | Water temperature sensor open | 
| 16 | Water temperature sensor short | 
| 17 | Evaporator temperature sensor open | 
| 18 | Evaporator temperature sensor short | 
| 19 | Temperature door potentiometer open/short | 
| 20 | Temperature door potentiometer fault | 
| 21 | Mode door potentiometer open/short | 
| 22 | Mode door potentiometer fault | 
| 25 | Intake door potentiometer open/short | 
| 26 | Intake door potentiometer fault | 
Fault code display
Continuance operation: DTC code is none or one.

Continuance operation: DTC code is two or more.

STEP operation
Normal or one fault code is same as a continuance operation.
DTC code is two or more.

If fault codes are displayed during the check, inspect malfunction causes by referring to fault codes table.
Fail safe
| No | Sensor | Fail condition | Fail safe function | 
| 1 | In-car sensor | < 0.1V or > 4.9V | 23℃ (73.4℉) | 
| 2 | Ambient temperature sensor | < 0.1V or > 4.9V | 20℃ (68℉) | 
| 3 | Evaporator temperature sensor | < 0.1V or > 4.9V | -2℃ (28.4℉) | 
| 4 | Temperature control actuator feedback | < 0.1V or > 4.9V | ● Setting temperature is 24.5℃ (76.1℉) or below: Max cool ● Setting temperature is 25.0℃ (77℉) or above: Max hot | 
| 5 | Mode control actuator feedback | < 0.1V or > 4.9V | ● Vent: Vent ● Others: Defog | 
| 6 | Intake actuator feedback | < 0.1V or > 4.9V | ● Recirculation: Recirculation ● Others: Fresh | 
| 10 | Engine coolant temperature | < 0.1V or > 4.9V | 85℃ (185℉) |