Item | Requirement | Remark |
Rated voltage | DC 12V | Shall activate normally in these range. |
Operating voltage range | DC 9 ~ 16V | |
Operating temperature range | -30°C ~ +75°C (-22°F ~ +167°F) | |
Storage temperature range | -40°C ~ +85°C (-40°F ~ +185°F) | |
Max humidity in use | 95% | |
High voltage resistance | 24V | |
Insulation resistance | 100MΩ or more (measured with 500V MEGGER) | Specify as well as parts that insulation like PCB, moisture-proof COATING is required |
Dark Current | Max 4mA | Measure when the state, all output loads are OFF and there are no Input SW(including TX operation) changes, continues 2sec. |
Voltage drop | 1.2V or less | Output terminals for POWER WINDOW RELAY shall be 2.0V or less |
NO | System name | Capacity |
1 | Room lamp | DC 12V 20W(Lamp load) |
2 | Power door relay | DC 12V 200mA(Inductive load) |
3 | Hazard relay | DC 12V 200mA(Inductive load) |
4 | Door lock relay | DC 12V 200mA(Inductive load) |
5 | Door unlock relay | DC 12V 200mA(Inductive load) |
6 | Driver door unlock relay | DC 12V 200mA(Inductive load) |
7 | Trunk release relay | DC 12V 200mA(Inductive load) |
8 | Tail lamp relay | DC 12V 200mA(Inductive load) |
9 | RPAS buzzer | DC 12V 60mA(Inductive load) |
10 | Horn relay | DC 12V 200mA(Inductive load) |
11 | Interior autocut | DC 12V 200mA(Inductive load) |