Removal and Installation
1.

Disconnect the battery negative terminal (A).

Tightening torquTightening torque

(-) terminal :

4.0 ~ 6.0N.m (0.4 ~ 0.6kgf.m, 3.0 ~ 4.4lb-ft)

2.

Disconnect the breather hose (B), air intake hose (C) and then remove the air cleaner assembly (D).

Tightening torque

Hose clamp bolt:

2.9 ~ 4.9N.m (0.3 ~ 0.5kgf.m, 2.2 ~ 3.6lb-ft)

Air cleaner assembly bolts:

7.8 ~ 11.8N.m (0.8 ~ 1.0kgf.m, 5.8 ~ 7.2lb-ft)

3.

Disconnect the battery positive terminal (A) and then remove the battery (B).

Tightening torque

(+) terminal :

7.8 ~ 9.8N.m (0.8 ~ 1.0kgf.m, 5.8 ~ 7.2lb-ft)

4.

Disconnect the connectors (A) and then remove the ECM (B).

Tightening torque :

9.8 ~ 11.8N.m (1.0 ~ 1.2kgf.m, 7.2 ~ 8.7lb-ft)

5.

Remove the battery tray (A).

Tightening torque :

9.8 ~ 11.8N.m (1.0 ~ 1.2kgf.m, 7.2 ~ 8.7lb-ft)

6.

Installation is the reverse order of removal.

caution

When installing the battery, fix the mounting bracket on the tray correctly.