The Evaporator sensor located on heater unit detects the core temperature. It is a negative type thermistor whose resistance is inversely proportional to temperature. Evaporator sensor transforms measured temperature into voltage value and delivers it to A/C ECU. when core temperature is blow threshold value, A/C ECU interrupts compressor relay power, in order to prevent evaporator freezing by excessive cooling.
Air conditioner Control Module sets DTC B1241 if Evaporator sensor has been detected below 0.1V for 4 seconds.
| Item | Detecting Condition | Possible Cause | 
| DTC Strategy | 
										•
									 Voltage check | 1. Short circuit in harness 2. Faulty Evaporator sensor 3. Faulty A/C Control Unit | 
| Enable Conditions | 
										•
									 IG KEY ON | |
| Threshold value | 
										•
									 Evaporator sensor has been detected below 01.V for 4 seconds. | |
| Failsafe | 
										•
									 Control with the value of -2℃(28.4℉) | 
| Temperature(℃/℉) | Resistance(㏀) | Temperature(℃/℉) | Resistance(㏀) | 
| -10/-14 | 18 | 20/68 | 4.8 | 
| 0/32 | 11 | 30/86 | 3.3 | 
| 10/50 | 7.3 | 40/104 | 2.3 |