Component Location
General Description

The ambient temperature sensor located at the center stay of the condensor detects ambient air temperature. It is a negative type thermistor whose resistance is inversely proportional to temperature. Its output is used for sensor fail-safe, temperature regulation door lock, blower motor level control, mix mode control and in-car humidity control.

DTC Description

Air conditioner Control Module sets DTC B1238 if Ambient sensor has been detected over 4.9V for 4 seconds.

DTC Detecting Condition

Item

Detecting Condition

Possible Cause

DTC Strategy

Voltage check

1.

Poor Connection in harness

2.

Open in signal circuit

3.

Shrot to battery in signal circuit

4.

Faulty Ambient Temperature sensor

5.

Faulty air condtioner control Module

Enable Conditions

IG KEY ON

Threshold value

Ambient Temperature sensor has been detected over 4.9V for 4 seconds.

Failsafe

Displayed '--' and A/C control Module regards and controls it as 20℃(68℉)

Specification
※ Resistance value of ambient temp.sensor as a function of temperature.

Temperature(℃/℉)

Resistance(㏀)

Temperature(℃/℉)

Resistance(㏀)

-20/-4

284.5

50/122

10.8

0/32

97.5

70/158

5.2

25/77

30

Diagnostic Circuit Diagram