The mode control actuator mounted on heater unit adjusts position of mode door by operating Direction Motor based on signal of A/C control unit. Pressing mode select switch makes the mode control actuator shift in order of vent→ B/L → floor → mix.
Air conditioner Control Module sets DTC B1249 if Feedback signal of Mode Actuator has been detected below 0.1V for 100ms.
| Item | Detecting Condition | Possible Cause | 
| DTC Strategy | 
										•
									 Voltage check | 1. Poor Connection in harness 2. Open in signal (Feedback signal), Power or Gruoud circuit 3. Faulty Mode Actuator 4. Faulty Air conditioner Control Unit | 
| Enable Conditions | 
										•
									 IG KEY ON | |
| Threshold value | 
										•
									 Feedback signal of Mode Actuator has been detected below 0.1V for 100ms. | |
| Failsafe | 
										•
									 If the Mode actuator is placed at Vent mode right before fail detection, Actuator is operated and fixed to Vent Mode Postion. 
										•
									 The others mode are selected, Actuator is moved to DEF mode position | 
| Mode Door Position | Voltage | 
| VENT | 0.45±0.3V | 
| BI-LEVEL | 1.4±0.3V | 
| FLOOR | 2.45±0.3V | 
| MIX | 3.5±0.3V | 
| DEF | 4.55±0.3V |