The mode control actuator is mounted at the heater control unit. The mode control actuator consists of a motor and a feedback potentiometer. Pressing mode select switch makes the mode control actuator shift in order of vent→ B/L → floor → mix.
Air conditioner Control Module sets DTC B1250 if Feedback signal of Mode Actuator has been detected over 4.9V for 100ms.
| Item | Detecting Condition | Possible Cause | 
| DTC Strategy | 
										•
									 Voltage check | 1. Short in signal circuit(Feedback signal) 2. Faulty Mode Actuator 3. Faulty Air conditioner Control Module | 
| Enable Conditions | 
										•
									 IG KEY ON | |
| Threshold value | 
										•
									 Feedback signal of Mode Actuator has been detected over 4.9V for 100ms. | |
| Failsafe | 
										•
									 If the Mode actuator is placed at Vent mode right before fail detection, Actuator is operated and fixed to Vent Mode Postion. 
										•
									 In case of the others, Actuator is moved to DEF mode position | 
| Mode Door Position | Voltage | 
| VENT | 0.45±0.3V | 
| BI-LEVEL | 1.4±0.3V | 
| FLOOR | 2.45±0.3V | 
| MIX | 3.5±0.3V | 
| DEF | 4.55±0.3V |