The mode control actuator mounted on heater unit adjusts position of mode door by operating Direction Motor in accordance with signal of A/C control unit. Pressing mode select switch makes the mode control actuator shift in order of vent→ B/L → floor → mix.
Air conditioner Control Module sets DTC B2409 if Feedback signal of Driver Direction actuator has not been moved to the mode,where air condition control module controls, within 10 seconds.
| Item | Detecting Condition | Possible Cause | 
| DTC Strategy | 
										•
									 Voltage check | 1. Poor contact in harness 2. Open or short in motor power circuit 3. Faulty Driver Direction actuator 4. Faulty air conditioner control module | 
| Enable Conditions | 
										•
									 IG KEY ON | |
| Threshold value | 
										•
									 No movement to controlled mode position for 10 seconds. | |
| Failsafe | 
										•
									 Fixed as current position | 
| Mode Door Position | Voltage | 
| VENT | 0.45±0.3V | 
| BI-LEVEL | 1.4±0.3V | 
| FLOOR | 2.45±0.3V | 
| MIX | 3.5±0.3V | 
| DEF | 4.55±0.3V |