Inspection
1.

Turn the ignition switch OFF.

2.

Disconnect the temperature control actuator connector.

3.

Verify that the temperature control actuator operates to the warm position when connecting 12V to the terminal 4 and grounding terminal 3.

Verify that the temperature control actuator operates to the cool position when connecting in the reverse.

1. -

2. -

3. Cool position

4. Warm position

5. Sensor (+ 5V)

6. Feedback

7. Sensor ground

4.

Connect the temperature control actuator connector.

5.

Turn the ignition switch ON.

6.

Check the voltage between terminal 6 and 5.

Specification

Door position

Voltage (V)

Error detecting

Max. cooling

0.45

Low voltage : 0.1V or less

Max. heating

4.55

High voltage : 4.9V or more

It will feedback current position of actuator to controls.

7.

If the measured voltage is not specification, substitute with a known-good temperature control actuator and check for proper operation.

8.

If the problem is corrected, replace the temperature control actuator.

Replacement
1.

Disconnect the negative (-) battery terminal.

2.

Disconnect the connector and then remove the temperature control actuator (A) after loosening the mounting screws.

3.

Installation is the reverse order of removal.