Component Location
General Description

The air mix actuator(Temperature Actuator) is located at heater unit. It contains a motor that changes temp door position and a potentiometer that monitors the position of the temp door. The Air Conditioning Control Unit controls the temperature by commanding the temp door motor to move.

DTC Description

The Airconditioner Control Module sets DTC B1205 if the Feed Back signal of Passenger Air mix actuator(Temperature actuator) has been detected over 4.9V for 0.3 seconds.

DTC Detecting Condition

Item

Detecting Condition

Possible Cause

DTC Strategy

•

Voltage check

1.

Short to battery in signal(Feedback) circuit.

2.

Faulty passenger air mix actuator.

3.

Faulty A/C control unit.

Enable Conditions

•

IG KEY ON

Threshold value

•

Feedback ciruit has been detected over 4.9V for 0.3 seconds.

Failsafe

•

setting temperature :16℃(62.6℉)-24℃(76.1℉) fix at max. cooling position

•

setting temperature : 25℃(77℉)-31℃(89.6℉) fix at max. heating position

Specification

※ Voltage value of Air Mix potentiometer as a function of temp door position.

Door position

Voltage

Max. cool

0.3±0.15V

Max. warm

4.7±0.15V

Diagnostic Circuit Diagram
Яндекс.Метрика