Componet Location
General Description

The mode control actuator mounted on heater unit adjusts position of mode door by operating Direction Motor based on signal of A/C control unit. Pressing mode select switch makes the mode control actuator shift in order of vent→ B/L → floor → mix.

DTC Description

DTC B1250 sets if Mode Actuator sensor signal is at or over 4.9V for 0.3 seconds.

DTC Detecting Condition

Item

Detecting Condition

Possible Cause

DTC Strategy

•

Voltage check

1.

Short in signal circuit(Feedback signal)

2.

Faulty Mode Actuator

3.

Faulty Air conditioner Control Module

Enable Conditions

•

Ignition ON

Threshold value

•

Mode Actuator sensor signal is at or over 4.9V for 0.3 seconds

Failsafe

•

If the Mode actuator is placed at Vent mode right before fail detection, Actuator is operated and fixed to Vent Mode Postion.

•

In case of the others, Actuator is moved to DEF mode position

Specification

※ Voltage value of potentiometer as a function of mode door position.

Mode Door Position

Voltage

VENT

0.3±0.15V

BI-LEVEL

1.4±0.4V

FLOOR

2.5±0.4V

MIX

3.6±0.4V

DEF

4.7±0.15V

Diagnostic Circuit Diagram