Description
Burglar Alarm System

The burglar alarm system is armed automatically after the doors, hood, and trunk lid are closed and locked.

The system is set off when any of these things occur:

A door is forced open.

A door is unlocked without using the transmitter & key.

The trunk lid is opened without using the key.

The hood is opened.

The engine starter circuit and battery circuit are bypassed by breaking the ignition switch.

When the system is set off, the alarm (horn) sounds and the hazard lamp flash for about two minutes or until the system is disarmed by unlocking the transmitter.

For the system to arm, the ignition switch must be off and the key removed. Then, the body control module must receive signals that the doors, hood, and trunk lid are closed and locked. When everything is closed and locked, none of the control unit inputs are grounded.

The door switches, hood switch and trunk lid switch are all close and lock the doors with the remote transmitter and then the system arms after 30 second.

If anything is opened or improperly unlocked after the system is armed, the body control module gets a ground signal from that switch, and the system is set off.

If one of the switches is misadjusted or there is a short in the system, the system will not arm. As long as the body control module continues to get a ground signal, it thinks the vehicle is not closed and locked and will not arm.

The receiver is integrated in the body control module.

Keyless Entry System

The burglar alarm system is integrated with the keyless entry system. The keyless entry system allows you to lock and unlock the vehicle with the remote transmitter. When you push the lock button, all doors lock. When you push the unlock button all doors unlock.

The room lamp, if its switch is in the center position, will come on when you press the unlock button. If you do not open a door, the light will go off in about 30 seconds, the doors will automatically relock, and the burglar alarm system will rearm. If you relock the doors with the remote transmitter within 30 seconds, the light will go off immediately.

You cannot lock or unlock the doors with the remote transmitter if the key is in the ignition switch.

The system will signal you when the doors lock and unlock by flashing the hazard lamp once when they lock, and twice when they unlock.

Data Flow
Overview Description
1.

According to various input signals there are a variety of changing conditions that perform many functions.

A.

ARM

B.

ARM WAIT

C.

AUTO lock TIMER1

D.

AUTO lock TIMER2

E.

ARM HOLD

F.

REARM

G.

ALARM

H.

PREARM

I.

DISARM

Condition 1 : At least one entrance opened

(4Door Not Close=ON) or (Trunk Open Switch=ON) or (Hood Switch=ON)

Condition 2 : All doors closed, but HOOD or TRUNK open

(4Door Not Close=OFF) & (Trunk Open Switch=ON) or (Hood Switch=ON)

Condition 3 : Close the 4DOOR with DOOR lock

(4Doors Locked) & (4Door Not Close ON→OFF)

Condition 2 & 3 : Close the 4DOOR with lock with HOOD or TRUNK OPEN

(4Doors Locked) & (4Door Not Close ON→OFF) & (Trunk Open Switch=ON) or (Hood Switch=ON)

All entrances closed : 4DOOR Switch & HOOD Switch & TRUNK OPEN Switch is CLOSE

LOCK : Lock command by Tx

UNLOCK : Unlock command by Tx

LOCK : Driver key lock switch is ON

UNLOCK : Driver key unlock switch is ON

TRUNK : TRUNK OPEN signal or TRUNK or RKE TRUNK command by Tx

IGN KEY ON : KEY IN Switch = ON & IGN1 = ON & IGN2 =ON

IGN KEY OUT : KEY IN Switch = OFF & IGN1 = OFF & IGN2 =OFF

KEY IN : KEY IN Switch = ON

KEY IN 1 : KEY IN Switch = ON or IGN1 = ON or IGN2 = ON

H1 : Hazard Time is one-time(lock) 1sec on

H2 : Hazard Time is two-time(unlock) 0.5sec/on, 0.5sec/off

AUTO LOCK TIMER1 : 30sec

AUTO LOCK TIMER2 : 30sec

ARM WAIT TIMER : 30sec

TRUNK TIMER : 30sec

TRUNK MARK : Default value is clear

LOCK CONFIRM CHECK : 0.2 ~ 5sec

Security Ind Control
1.

Key In switch ON or ACC ON1 ON or IGN1 ON or IGN2 ON or FOB IN is LED OFF.

2.

IGN KEY OUT entry in the ARM WAIT mode, the Infinite On control of the ARM WAIT mode, the other will control the BLINKING.

3.

BLINKING cycle is 2.3s.(ON during 0.3s / OFF during 2.0s)

T1 : 0.3sec, T2 : 2sec

Functions
DISARM
Condition 1

State

Description

Initial Condition

ALARM

Event

-

IGN KEY ON during 30sec or ALT ”L” on

NON SMK SPEC :

-

Any door open & TX unlock

-

TX Trunk

-

TX Lock & Lock confirm Failed

SMK SPEC :

-

Any door open & RKE CMD Unlock/ Passive Access Unlock 1

-

RKE trunk 1

-

TP AUTH 1/ PIC AUTH 1

-

RKE CMD Lock/ Passive Access Lock 1 & Lock confirm Failed

Mechanical Key Option Enable :

-

Unlock

-

lock & Lock confirm Failed

Action

The state goes to DISARM state

-

Horn Relay, Hazard Relay, Start inhibit OFF

-

TX Unlock, RKE CMD Unlock, Passive Access Unlock 1

-> Unlock relay on for 0.5sec

-> Hazard relay on (TWICE)

Lock failure : Lock attempts within 5 seconds after the Unlock door maintain at least one if

RKE CMD = Unlock : RKE CMD = Unlock & Fob1 or Unlock & Fob2

RKE CMD = Lock : RKE CMD = Lock & Fob1 or Lock & Fob2

T1 : 0.5s, T2 : 0.5s +-0.1s

Condition 2

State

Description

Initial Condition

DISARM state & (IGN KEY OUT) & Any Door open

Event

NON SMK spec :

-

Any door open & TX UNLOCK

SMK spec :

-

Any door open & RKE CMD UNLOCK / Passive Access Unlock 1 / RKE TRUNK 1

-

TP AUTH 1 / PIC AUTH 1

Action

No state change

-

TX UNLOCK, RKE CMD UNLOCK, Passive Access Unlock 1

-> Hazard relay for 0.5s ON/OFF(twice)

Condition 3

State

Description

Initial Condition

ARM WAIT state

Event

-

Any door open or Hood switch OPEN or Trunk switch OPEN

-

Any door is unlocked

-

Key In switch ON

SMK spec :

TP AUTH 1 / PIC AUTH 1

Mechanical Key OPTION Enable :

UNLOCK

Action

The state goes to DISARM state

Condition 4

State

Description

Initial Condition

AUTOLOCK TIMER1 STATE

Event

-

Any door open or Hood switch OPEN or Trunk switch OPEN

-

Key In switch ON

-

AUTO LOCK & Lock confirmation failure

NON SMK spec :

-

AUTO LOCK & Lock confirmation failure

SMK spec :

-

RKE CMD LOCK / Passive Access Lock 1& Lock confirmation failure

-

TP AUTH 1 / PIC AUTH 1

Mechanical Key option Enable :

-

LOCK & Lock confirmation failure

Action

The state goes to DISARM state

Condition 5

State

Description

Initial Condition

AUTOLOCK TIMER2 STATE

Event

-

Any door open

-

Key In switch ON

-

AUTO LOCK & Lock confirmation failure

-

Hood switch Open and Memory Hood was Close

-

Trunk switch Open and Memory Trunk was Close

NON SMK spec :

-

TX LOCK& Lock confirmation failure

SMK spec :

-

RKE CMD=LOCK/ Passive Access Lock 1& Lock confirmation failure

-

TP AUTH 1/PIC AUTH 1

Mechanical Key option Enable :

LOCK & Lock confirmation failure

Action

The state goes to DISARM state

Condition 6

State

Description

Initial Condition

ARM STATE

Event

-

IGN KEY ON

SMK spec :

-

TP AUTH 1 / PIC AUTH 1

Mechanical Key option Enable :

-

UNLOCK

Action

The state goes to DISARM state

Condition 7

State

Description

Initial Condition

REARM state

Event

-

IGN KEY ON during 30sec or ALT”L” on

NON SMK spec :

-

TX LOCK& Lock confirmation failure

-

TX TRUNK

SMK spec :

-

TP AUTH 1 / PIC AUTH 1

-

RKE CMD LOCK / Passive Access Lock 1 & Lock confirmation failure

-

RKE TRUNK 1

Mechanical Key option Enable :

-

UNLOCK

-

LOCK & Lock confirmation failure

Action

The state goes to DISARM state

Start inhibit OFF

Condition 8

State

Description

Initial Condition

PREARM state

Event

-

Key In switch ON

-

All entrance closed & Any Door is unlocked

-

Any Door open & Tx Unlock

NON SMK :

-

Any door open & TX UNLOCK

SMK :

-

TP AUTH 1 / PIC AUTH 1

-

Any door open & RKE CMD UNLOCK/ Passive Access Unlock 1

Mechanical Key option Enable :

-

UNLOCK

Action

The state goes to DISARM state

-

TX UNLOCK, RKE CMD UNLOCK, Passive Access Unlock 1

-> Hazard relay for 0.5s ON/OFF(twice)

Condition 9

State

Description

Initial Condition

ARMHOLD

Event

-

IGN KEY ON

SMK :

-

TP AUTH 1 / PIC AUTH 1

Mechanical Key option Enable :

-

UNLOCK

Action

The state goes to DISARM state

ARM
Condition 1

State

Description

Initial Condition

ARM state

Event

NON SMK :

-

TX LOCK

NON SMK :

-

RKE CMD LOCK / Passive Access Lock 1

Action

No state change

Hazard relay 1Time on(1sec)

Condition 2

State

Description

Initial Condition

ARM WAIT state

Event

-

After ARM WAIT TIMER finished

Action

The state goes to ARM state

Condition 3

State

Description

Initial Condition

ARMHOLD state

Event

Trunk close for at least Trunk Release Time Out(default 30sec) in ARMWAIT state

Action

The state goes to ARM state

ALARM
Condition 1

State

Description

Initial Condition

ARM state

Event

Any door open or Hood switch open or Trunk switch open

Action

The state goes to ALARM state

-

Engine Start Inhibit is ON

-

The horn is ON one time for 27sec(±2sec) and OFF two times for 10sec(±1sec)

-

The hazard is driven also (During Horn driving)

T1 : 27s(±2sec), T2 : 10s(±2sec), T3 : 0.5s ± 0.1sec

Note : Horn Output : Period : 1sec(Can be calibrated Horn Period), 50% Duty

Condition 2

State

Description

Initial Condition

REARM state

Event

Any door open or Hood switch OPEN or Trunk switch OPEN

Action

The state goes to ALARM state

The horn is ON one time for 27sec(±2sec) and OFF two times for 10sec(±1sec)

The hazard is driven also (During Horn driving)

Condition 3

State

Description

Initial Condition

ARMHOLD state

Event

Any door open or Hood switch OPEN

Action

The state goes to ALARM state

The horn is ON one time for 27sec(±2sec) and OFF two times for 10sec(±1sec)

The hazard is driven also (During Horn driving).

ARM WAIT MODE
Condition 1

State

Description

Initial Condition

ARMWAIT state

Event

NON SMK :

-

TX LOCK

NON SMK :

-

RKE CMD LOCK / Passive Access Lock 1

Action

No state change

Hazard relay 1Time on(1sec)

Condition 2

State

Description

Initial Condition

DISARM state & IGN KEY OUT & All entrances closed(DOORS, HOOD and TRUNK)

Event

NON SMK :

-

Tx Lock & locked confirmed

SMK spec :

-

RKE CMD LOCK / Passive Access Lock 1 & locked confirmed

Mechanical Key option Enable :

-

LOCK & locked confirmed

-

DOOR LOCK state : Any door open → All door closed

Action

-

The state goes to ARMWAIT State

-

Start ARM WAIT TIMER

-

Hazard relay 1Time on(1sec)

Condition 3

State

Description

Initial Condition

ALARM state & All entrances closed(DOORS, HOOD and TRUNK)

Event

NON SMK :

-

Tx Lock & locked confirmed

SMK spec :

-

RKE CMD LOCK / Passive Access Lock 1 & locked confirmed

Mechanical Key option Enable :

-

LOCK & locked confirmed

Action

-

The state goes to ARMWAIT State

-

Horn relay, Start inhibit relay OFF

-

Hazard relay 1Time on(1sec) (LOCK : Except)

-

Start ARMWAIT TIMER

Condition 4

State

Description

Initial Condition

AUTOLOCK TIMER1 state

Event

AUTOLOCK & locked confirmed

NON SMK :

-

Tx Lock & locked confirmed

SMK :

-

RKE CMD LOCK / Passive Access Lock 1 & locked confirmed

Mechanical Key option Enable :

LOCK & locked confirmed

Action

-

The state goes to ARMWAIT State

-

Hazard relay 1Time on(1sec)

-

Start ARMWAIT TIMER

Condition 5

State

Description

Initial Condition

PREARM state

Event

All door closed and (Trunk switch CLOSE & TRUNK MARK CLEAR) & Hood switch CLOSE & DOOR LOCK

Action

-

The state goes to ARMWAIT State

-

Hazard relay 1Time on(1sec)

-

Start ARMWAIT TIMER

Condition 6

State

Description

Initial Condition

REARM state

Event

NON SMK :

-

TX LOCK & locked confirmed

SMK :

-

RKE CMD LOCK/ Passive Access Lock 1 & locked confirmed

Mechanical Key option Enable :

-

LOCK & locked confirmed

Action

-

The state goes to ARMWAIT State

-

Hazard relay 1Time on(1sec) (LOCK : Except)

-

Start Inhibit relay OFF

-

Start ARMWAIT TIMER

*1 : Lock : Driver Door Unlock Switch or Assist Door Unlock Switch or Rear Right Driver Unlock Switch = LOCK

Unlock : Driver Door Unlock Switch or Assist Door Unlock Switch or Rear Right Driver Unlock Switch = UNLOCK

REARM MODE
Condition 1

State

Description

Initial Condition

ALARM state

Event

All door closed and trunk switch close, hood switch close state, and ALARM PATTERN finished

Action

The state goes to REARM state

AUTO LOCK TIMER1 MODE
Condition 1

State

Description

Initial Condition

ARM state

Event

NON SMK :

-

TX UNLOCK

SMK :

-

RKE CMD UNLOCK / Passive Access Unlock 1

Action

-

The state goes to AUTO LOCK TIMER1 state

-

Start AUTO LOCK TIMER1

-

Hazard relay Twice on(0.5s ON/0.5s OFF)

Condition 2

State

Description

Initial Condition

AUTO-LOCK TIMER1 state

Event

AUTOLOCK TIMER1 finished

NON SMK :

-

TX UNLOCK

SMK :

-

RKE CMD UNLOCK / Passive Access Unlock 1

Action

No change state

CASE1: AUTO LOCK TIMER1 Finished

AUTOLOCK

CASE2: TX UNLOCK, RKE CMD UNLOCK, Passive Access Unlock 1

Hazard relay Twice on(0.5s ON/0.5s OFF)

Restart AUTO LOCK TIMER1

Condition 3

State

Description

Initial Condition

ARM WAIT state

Event

NON SMK :

TX UNLOCK

SMK :

RKE CMD UNLOCK / Passive Access Unlock 1

Action

-

The state goes to AUTO LOCK TIMER1 state

-

Start AUTO LOCK TIMER1

-

Hazard relay Twice on(0.5s ON/0.5s OFF)

Condition 4

State

Description

Initial Condition

DISARM state & All entrances closed(DOORS, Hood SW & Trunk SW) & IGN KEY OUT

Event

NON SMK :

TX UNLOCK

SMK :

RKE CMD UNLOCK/ Passive Access Unlock 1

Action

-

The state goes to AUTO LOCK TIMER1 state

-

Start AUTO LOCK TIMER1

-

Hazard relay Twice on(0.5s ON/0.5s OFF)

Condition 5

State

Description

Initial Condition

ALARM state & All door closed and Trunk switch CLOSE, Hood switch CLOSE

Event

NON SMK :

TX UNLOCK

SMK :

RKE CMD UNLOCK / Passive Access Unlock 1

Action

-

The state goes to AUTO LOCK TIMER1 state

-

Start AUTO LOCK TIMER1

-

Hazard relay Twice on(0.5s ON/0.5s OFF)

-

Start inhibit relay off /Horn relay off

Condition 6

State

Description

Initial Condition

REARM state

Event

NON SMK :

TX UNLOCK

SMK :

RKE CMD UNLOCK/ Passive Access Unlock 1

Action

The state goes to AUTO LOCK TIMER1 state

-

Start AUTO LOCK TIMER1

-

Hazard relay Twice on(0.5s ON/0.5s OFF)

-

Start inhibit relay off

AUTO LOCK TIMER2 MODE
Condition 1

State

Description

Initial Condition

AUTO-LOCK TIMER2 state

Event

Finished AUTO LOCK TIMER2

NON SMK :

TX UNLOCK

SMK :

RKE CMD UNLOCK/ Passive Access Unlock 1

Action

No change state

CASE1: AUTO LOCK TIMER2 finished

AUTOLOCK

CASE2: TX UNLOCK, RKE CMD UNLOCK, Passive Access Unlock 1

-

Start AUTOL OCK TIMER2

-

Hazard relay Twice on(0.5s ON/0.5s OFF)

Condition 2

State

Description

Initial Condition

DISARM state & IGN KEY OUT & (Trunk switch OPEN or Hood switch OPEN) state

Event

NON SMK :

TX UNLOCK

SMK :

RKE CMD UNLOCK/ Passive Access Unlock 1

Action

-

The state goes to AUTOLOCKTIMER2 state

-

Start AUTOLOCKTIMER2

-

Hazard relay Twice on(0.5s ON/0.5s OFF)

-

Memo Hood/Trunk state

Condition 3

State

Description

Initial Condition

ALARM state & All door closed  & (Trunk switch OPEN or Hood switch OPEN) state

Event

NON SMK :

TX UNLOCK

SMK :

RKE CMD UNLOCK / Passive Access Unlock 1

Action

-

The state goes to AUTO LOCK TIMER2 state

-

Horn relay, Start inhibit relay OFF

-

Start AUTO LOCK TIMER2

-

Hazard relay Twice on(0.5s ON/0.5s OFF)

-

Memo Hood/Trunk state

Condition 4

State

Description

Initial Condition

PREARM state & All door closed & (Trunk switch OPEN or Hood switch OPEN)state

Event

NON SMK :

TX UNLOCK

SMK :

RKE CMD UNLOCK / Passive Access Unlock 1

Action

-

The state goes to AUTO LOCK TIMER2 state

-

Start AUTO LOCK TIMER2

-

Hazard relay Twice on(0.5s ON/0.5s OFF)

-

Memo Hood/Trunk state

Condition 5

State

Description

Initial Condition

ARMHOLD state

Event

NON SMK :

TX UNLOCK

SMK :

RKE CMD UNLOCK / Passive Access Unlock 1

Action

-

The state goes to AUTO LOCK TIMER2 state

-

Start AUTO LOCK TIMER2

-

Hazard relay Twice on(0.5s ON/0.5s OFF)

-

Memo Hood/Trunk state

PREARM MODE
Condition 1

State

Description

Initial Condition

AUTO-LOCK TIMER2 state

Event

AUTO LOCK & locked confirmed

NON SMK :

TX LOCK& locked confirmed

SMK :

RKE CMD LOCK/ Passive Access Lock 1 & locked confirmed

Mechanical Key option Enable :

LOCK & locked confirmed

Action

The state goes to PREARM state

Condition 2

State

Description

Initial Condition

DISARM state & IGN KEY OUT

Event

NON SMK :

-

Any door open or Hood SW OPEN or Trunk SW OPEN state & locked confirmed

SMK :

-

Any door open or Hood SW OPEN or Trunk SW OPEN state RKE CMD LOCK / Passive Access Lock 1 & locked confirmed

Mechanical Key option Enable :

LOCK & locked confirmed

ALL DOOR LOCK state (Any door open → All doors closed) and (Trunk switch OPEN or Hood switch OPEN)

Action

The state goes to PREARM state

Condition 3

State

Description

Initial Condition

ALARM state & IGN KEY OUT and(Any door open or Hood SW OPEN or Trunk SW OPEN)

Event

NON SMK :

TX LOCK& locked confirmed

SMK :

RKE CMD LOCK/ Passive Access Lock 1 & locked confirmed

Mechanical Key option Enable :

LOCK & locked confirmed

Action

The state goes to PREARM state

Horn relay, Hazard relay, Start INH relay => OFF

Condition 4

State

Description

Initial Condition

ARMHOLD state

Event

NON SMK :

TX LOCK & locked confirmed

SMK :

RKE CMD LOCK/ Passive Access Lock 1& locked confirmed

Mechanical Key option Enable :

LOCK locked confirmed

Action

The state goes to PREARM state

Condition 5

State

Description

Initial Condition

ARMWAIT state

Event

NON SMK :

TX TRUNK

SMK :

RKE TRUNK 1

Action

The state goes to PREARM state

Start TRUNK TIMER

TRUNK MARK Set

Condition 6

State

Description

Initial Condition

PREARM  state

Event

Trunk switch OPEN

Trunk TimeR expired(Trunk Release Time Out: 30s)

Action

No state change

CASE Trunk switch OPEN :

Stop to Trun Timer.

TRUNK MARK  Clear

CASE TRUNK TIMER expired :

TRUNK MARK  Clear

ARMHOLD MODE
Condition 1

State

Description

Initial Condition

ARM state

Event

NON SMK :

TX Trunk

SMK :

RKE Trunk 1

Action

The state goes to ARMHOLD state

RESET
1.

In case of taking the BATTERY out during the ALARM state

Condition

State

Description

Initial Condition

ALARM, REARM state

Event

Taking the battery out

Action

Start INH relay ON and Horn relay twice

The state goes to ALARM mode

2.

In case of taking the BATTERY out during ARM

Condition

State

Description

Initial Condition

ARM state

Event

Taking the battery out

Action

The state goes to ARM mode

3.

In case of taking the BATTERY out during the ARMHOLD state

Condition

State

Description

Initial Condition

Except ARM, ALARM, REARM,ARMHOLD state

Event

Taking the battery out

Action

The state goes to DISARM mode