Removal and Installation
1.

Remove the air duct (A).

2.

Disconnect the terminals (B) from the battery. The negative terminal first.

Tightening torque :

(+) terminal (A) : 7.8 ~ 9.8N.m (0.8 ~ 1.0kgf.m, 5.8 ~ 7.2lb-ft)

(-) terminal (B) : 4.0 ~ 6.0N.m (0.4 ~ 0.6kgf.m, 3.0 ~ 4.4lb-ft)

3.

Remove the battery insulation pad.

4.

Remove the battery mounting bracket by loosening the mounting bolt and then remove the battery (C).

Tightening torque :

9.8 ~ 11.8N.m (1.0 ~ 1.2kgf.m, 7.2 ~ 8.7lb-ft)

5.

Remove the air cleaner assembly mounting bolts (A).

Tightening torque :

7.8 ~ 9.8N.m (0.8 ~ 1.0kgf.m, 5.8 ~ 7.2lb-ft)

6.

Disconnect the front connector (A) and then remove the battery tray (B).

Tightening torque :

9.8 ~ 11.8N.m (1.0 ~ 1.2kgf.m, 7.2 ~ 8.7lb-ft)

7.

Installation is the reverse order of removal.

caution

When installing the battery, fix the mounting bracket on the tray correctly.

Яндекс.Метрика